Monica
Question
Hello. Is it possible to treat the carpet flooring located in the escape routes and what compound it is better to use? What will be the class of fire hazard after the treatment? (What kind of carpet flooring can be treated - natural or synthetic?).
Answer
Hello. Unfortunately, we can not offer any compounds out of our available product range. The promising developments are under the preliminary tests.

Date:  08/15/2012 04:00:00 am
Egen
Question
One year ago I bought the fire-retardant compound OBEREG-OB (Standard). During this period the bag has become wet. Have the compound lost its properties or not?
Answer
The fire retardant compound haven’t lost its properties. Due to the hygroscopic properties of the compound it is necessary to completely deplete the package. But if the compound is caked, it is recommended to dissolve it in warm or hot water.

Date:  08/14/2012 04:00:00 am
Sergey
Question
Hello! I have a question about the fire-retardant powder OBEREG-OB (Standard). Why the consumption rate of the dry compound per square meter was greater than it is now? Why the consumption rate has been decreased, but the composition of the fire-retardant compound has not changed? Is the consumption rate specified in the certificate-manual mandatory, or it is the recommendation only? Thank you in advance!
Answer
Dear Sergey! Since April 26, 2012 the fire-retardant impregnation OBEREG-OB is manufactured according to the new technical specifications with a fundamentally new formulation. The effectiveness of compound has been confirmed by the certificate of conformance and test report. As for the consumption standards recommended in the certificate, we can provide the following information. During examination of the fire-retardant effectiveness of the compound (according to GOST 53292-2009), the tests are carried out using the samples with average characteristics (dried, fineline wood). For the qualitative treatment of specific objects it is necessary to change the amount of working solution applied in accordance with the wood condition. The standards recommended in the certificate have been obtained by an experimental approach and confirmed by periodic tests. If it is not possible to observe the recommended consumption rates, it may lead to the wood treatment of insufficient quality and reduction of the guaranteed life of protection.

Date:  07/01/2012 04:00:00 am



January 30 in the Leninsky district of Novosibirsk caught fire one of the apartments on the second floor of the five-story building. Residents were evacuated from the house. To the house called the fire Department.
Read more

For several years, visitors complain about the unsatisfactory condition of the Kuibyshev Central district hospital. The building has not known normal repair for a long time. The walls of the building inside and outside are covered with cracks, in many corners lives abundant mold.
Read more
subscribe to news and articles

One of the most important aspects of our homes is the safety factor. Okay, we all love the idea of living in a beautiful house or apartment complete with awesome interior furnishings but the bottom line is always the same; how safe is your home? With this sobering thought in mind, let’s look at an extremely unobtrusive way to ensure that you and your loved ones are looked after should the unthinkable happen. Yes, we are talking about flame retardant exterior paint!
Read more

The very thought of fire grips the mind with fear and panic. Overwhelming heat, suffocating smoke, loss of property, and above all else, the loss of life. The insurance company may be able to replace the material goods, but there are some things that money simply cannot replace – lives, lost time and items of sentimental value.Fire strikes when least expected. It can start just about anywhere without warning, taking one by surprise and causing panic.    
Read more