Georg
Question
What is the validity period of the fire-retardant compound OBEREG-OB?
Answer
The validity period of the fire-retardant compound OBEREG-OB (Standard) is up to 8 years; OBEREG-OB (Professional) – up to 10 years; OBEREG-OB (Economy) - up to 12 years. These terms are valid provided for the wood treatment according to the 1st group of fire protection and operation at a humidity of not more than 80%.

Date:  02/01/2013 04:00:00 am
Nik
Question
You wrote that for the wood treatment at the low temperatures it is recommended to use the winter version of impregnation OBEREG-OB-YANTAR (M). Let me ask another question to clarify it. There is 20 degrees below zero outdoors. The freezing temperature of the compound is -25 degrees. Should I treat the wood surface? At what temperature the winter version of impregnation is used?
Answer
The winter version of impregnation is used, as a rule, at the low temperatures in order to prevent the crystallization of the compound. The temperature of 20 degrees below zero is higher than the freezing point of the compound, so the wood treatment is allowed. During treatment it is necessary to ensure the absence of ice on the surface to be treated, and in the case of fresh wood it is necessary to provide an increase in the compound consumption rate per square meter in accordance with the operating manual.

Date:  11/29/2012 04:00:00 am
Snork
Question
At what temperatures the fire-retardant impregnation of wooden structures OBEREG-OB-YANTAR can be used? Is it possible to use impregnation at the temperatures below -10?
Answer
For the treatment of wood at the low temperatures we recommend to use the winter version of impregnation – OBEREG-OB-YANTAR (M) http://zpo-obereg.ru/catalog/ognezashchita_sostavy/ognebiozashchitnaya-propitka-obereg-ob-yantar-m-zimniy/

Date:  11/28/2012 04:00:00 am



January 30 in the Leninsky district of Novosibirsk caught fire one of the apartments on the second floor of the five-story building. Residents were evacuated from the house. To the house called the fire Department.
Read more

For several years, visitors complain about the unsatisfactory condition of the Kuibyshev Central district hospital. The building has not known normal repair for a long time. The walls of the building inside and outside are covered with cracks, in many corners lives abundant mold.
Read more
subscribe to news and articles

One of the most important aspects of our homes is the safety factor. Okay, we all love the idea of living in a beautiful house or apartment complete with awesome interior furnishings but the bottom line is always the same; how safe is your home? With this sobering thought in mind, let’s look at an extremely unobtrusive way to ensure that you and your loved ones are looked after should the unthinkable happen. Yes, we are talking about flame retardant exterior paint!
Read more

The very thought of fire grips the mind with fear and panic. Overwhelming heat, suffocating smoke, loss of property, and above all else, the loss of life. The insurance company may be able to replace the material goods, but there are some things that money simply cannot replace – lives, lost time and items of sentimental value.Fire strikes when least expected. It can start just about anywhere without warning, taking one by surprise and causing panic.    
Read more